During Approved Document E Sound Testing, high levels of noise are generated but in order to make accurate test measurements, relatively quiet conditions are needed. Anyone working within the testing area will have to leave temporarily and any noisy works in the vicinity of the test areas including external site activity or ground works will need to be halted. Access is required for all the rooms being tested. Prior to testing, suitable couplings of test rooms, will be identified to enable a schedule of testing which may assist in controlling noise from other parts of the dvelopment to achieve the best possible testing environment.
How long will testing take?
The time taken for testing varies with site conditions, but generally a set of tests on houses takes about one to two hours and a set of tests on flats between two to three hours. During the test Soundguard Acoustics will require free uninterrupted access to the rooms in all test areas.
Can I observe the sound test?
Soundguard Acoustics will happily give you a brief overview of the test and demonstrate what we do, however, during the formal tests there are stringent rules restricting the number of personnel within the test areas so you will need to leave the engineer to it.
Should I inform my neighbours of the testing?
Noise levels are very high and if the building is attached in any way to occupied properties then it would be advisable to inform the residents as they are likely to hear the test. In some builds access to their property may be required. We recommend you check this with your BCO and request access to the neighbouring properties accordingly. Contact Soundguard Acoustics HERE for further advice regarding your Approved Doc E Sound Testing.
Showing posts with label ADE sound test. Show all posts
Showing posts with label ADE sound test. Show all posts
Monday, 2 December 2013
Monday, 18 November 2013
Customer Testimonials for Sound Testing
'Soundguard Acoustics provided a thorough & professional service & achieved a successful outcome for my building refurbishment project. I would definitely recommend them to anyone seeking expertise in this area' D. Widden, Taunton, Somerset
'We found Soundguard Acoustics competent, prompt & professional to work with. We will certainly be working with them again on future projects & would definitely recommend them to fellow professionals' L. Bullivant, BULLCO Ltd, Devon
'Soundguard Acoustics offered clear professional advice on our new product development work with Robust Detail Ltd. They responded quickly and we are very happy with the service received. We would definitely recommend them'M. Panes, Superglass
'Soundguard Acoustics provided a friendly service carried out in a prompt & professional manner' K. Thomas,Weston Super Mare
'We have always had a good service from Soundguard Acoustics. Friendly, reliable & reasonably priced' J. Pearce,DevonBuild.co.uk
'We found Soundguard Acoustics competent, prompt & professional to work with. We will certainly be working with them again on future projects & would definitely recommend them to fellow professionals' L. Bullivant, BULLCO Ltd, Devon
'Soundguard Acoustics offered clear professional advice on our new product development work with Robust Detail Ltd. They responded quickly and we are very happy with the service received. We would definitely recommend them'M. Panes, Superglass
'Soundguard Acoustics provided a friendly service carried out in a prompt & professional manner' K. Thomas,Weston Super Mare
'We have always had a good service from Soundguard Acoustics. Friendly, reliable & reasonably priced' J. Pearce,DevonBuild.co.uk
Thursday, 14 November 2013
Where do I find an Approved Doc E Sound Testing company?
Approved Document E states that the sound insulation testing body should be either a member of the Association of Noise Consultants (ANC) and have joined their PCT registration scheme or be registered testers with the United Kingdom Accreditation Service (UKAS).
Choosing an accredited company under these schemes gives you the peace of mind that your reports will be accepted by all local authorities, building control and national guarantee companies.
By using an ANC member registered under the PCT registration scheme, such as Soundguard Acoustics Ltd, then you will receive a full report including instruction for your Building Control Officer for accessing the secure online testing certificates for your build. Our company, Soundguard Acoustics, will also liaise with and release the report directly to your BCO if required to ensure that they are satisfied with the test selection.
What if I use an unregistered company?
Don’t! The quality and validity of the testing and results may be questionable and may not be accepted by the necessary approval bodies. It is likely that your BCO will ask for further or repeated testing by an accredited test company to validate the results. This will result in delay for your project and further payment to the accredited test company.
Choosing an accredited company under these schemes gives you the peace of mind that your reports will be accepted by all local authorities, building control and national guarantee companies.
By using an ANC member registered under the PCT registration scheme, such as Soundguard Acoustics Ltd, then you will receive a full report including instruction for your Building Control Officer for accessing the secure online testing certificates for your build. Our company, Soundguard Acoustics, will also liaise with and release the report directly to your BCO if required to ensure that they are satisfied with the test selection.
What if I use an unregistered company?
Don’t! The quality and validity of the testing and results may be questionable and may not be accepted by the necessary approval bodies. It is likely that your BCO will ask for further or repeated testing by an accredited test company to validate the results. This will result in delay for your project and further payment to the accredited test company.
Wednesday, 13 November 2013
How many Approved Doc E sound tests do I need within my development?
One set of tests needs to be undertaken for every ten flats or houses, provided the construction system is the same. A set means that the test should include two locations where the party element (wall or floor) is tested.
This is equivalent to two individual tests when assessing the performance of a wall (airborne performance only) and four individual tests when assessing a floor (two airborne and two impact tests). All tests must be undertaken between habitable spaces (e.g. bedrooms, living rooms) and not to or from common spaces such as stairwells and corridors.
Approved Document E 2003 states that a minimum of 10% of all party walls and floors is sound tested for every construction group or sub-group. This means that where variations in the construction may occur then further testing may be required.
Houses: a set of tests would usually comprise of two airborne sound insulation tests of a pair of separating walls
Flats: a set of tests would usually comprise of two airborne sound insulation tests on separating walls; two airborne sound insulation tests of separating floors and two impact sound transmission tests of separating floors
Rooms for Residential Purposes: (student residences, hotel rooms & care homes) a set of tests would usually comprise of one airborne sound insulation test of a separating wall; one airborne sound insulation test of a separating floor and one impact sound transmission test of a separating floor
Contact Soundguard Acoustics today for your advice or quotation for your testing requirements EMAIL
Wednesday, 23 October 2013
Approved Doc E Sound Testing
Approved Document E – ‘Resistance to the passage of sound’ came into force on July 1st 2003 and provides minimum sound insulation Building Regulation requirement for newly built and converted residential dwellings as well as the Code for Sustainable Homes. Properties include houses, flats, student residences, care homes, hotels and schools.
Approved Document E of the Building Regulations is a government-issued document providing guidance for architects, developers, building control bodies, building services engineers, and others involved in the design and conversion of buildings for residential purpose. The document explains the sound testing requirement and provides advice and details about building procedures and materials that affect test results.
Devon based, Soundguard Acoustics Ltd is approved under the Association of Noise Consultants (ANC) registration scheme for carrying out sound insulation testing (Registration number: 194-01) and will carry out sound tests across the South West and the UK.
The ANC scheme is supported by Approved Document E and ensures that sound insulation tests are carried out by suitably qualified and experienced staff, in accordance with the appropriate standards.
The scheme ensures that sound tests are properly traceable, audited and that you receive a fully documented report and certificate which will be easily recognised for approval by your local Building Control department.
If you require further advice with your project or end of build sound testing then please contact us.
Thursday, 24 January 2013
What is Sound Insulation Testing?
Developers are responsible for arranging testing to demonstrate compliance to Building Control that the Approved Doc E sound insulation regulations have been met. The procedure is more commonly referred to as pre-completion testing (PCT) or Approved Document E (ADE) sound testing.
What is Approved Doc E?
Approved Document E – ‘Resistance to the passage of sound’ came into force on July 1st 2003 and provides minimum sound insulation Building Regulation requirement for newly built and converted residential dwellings as well as the Code for Sustainable Homes. Properties include houses, flats, student residences, care homes, hotels and schools.
Approved Document E of the Building Regulations is a government-issued document providing guidance for architects, developers, building control bodies, building services engineers, and others involved in the design and conversion of buildings for residential purpose. The document explains the testing requirement and provides advice and details about building procedures and materials that affect test results
What is the benefit of a Sound Test?
In buildings sound can be defined as 'airborne sound' (i.e. sound generated and transferred directly in the air by talking or home entertainment systems) or 'impact sound' (i.e. sound generated by the impact of an object striking the floor and transmitted through it, such as footfall noise).
The objective of Approved Document E is to raise sound resistance standards for both airborne and impact noise between dwellings to provide reasonable living conditions and improve the standards of acoustic insulation in attached properties
Sound insulation testing may also be required in non-residential buildings such as schools, hospitals and workplaces to ensure that noise sensitive areas such as classrooms, wards and meeting rooms are suitably insulated from noisier areas
Do I need a sound test?
All new and converted dwelling houses and flats for residential purpose require sound testing to Approved Document E standard. This also includes a room or suite of rooms which is not a dwelling house or a flat but which is used by one or more persons to live and sleep. For example, rooms in hostels, hotels, boarding houses, halls of residence, and residential homes.
Detached properties do not require sound testing and new constructions that have been built and appropriately registered with the Robust Details scheme do not need to be sound tested. Historic building conversions may not need to be sound tested but often a ‘test and declare’ certificate for sound insulation performance is requested by the Building Control Officer (BCO).
Subscribe to:
Posts (Atom)