How quickly can I get Approved Doc E Sound Testing Results?

Where possible, Soundguard Acoustics will provide preliminary test results before we leave the site. We will follow this up with a fully documented and signed report with the ANC online access to your test certificates which will be emailed to you normally within 24 hours of your test. This can then be submitted to your BCO, we can submit the report directly to Building Control if you prefer. Printed copies are available if required.

Thursday, 28 November 2013

Approved Doc E - What do the numbers mean?

A sound insulation test of a separating partition will be considered as a pass if the airborne sound insulation is equal to or greater than the DnT,w + Ctr value required for the appropriate dwelling and if the impact sound insulation is equal to or less than the L’nT,w value for the appropriate dwelling. The performance criteria are different for new builds and conversions and also differences may occur due to the use of the dwelling type. 
   
DnT,w is an in-situ measured performance parameter which demonstrates the level of resistance to sound transmission between two adjacent spaces. The measurement will include both direct sound transmission and flanking sound transmission of the construction. Flanking transmission is the effect of sound travelling through the building and may be particularly evident where beams and joists bridge a common partition or along poorly isolated lightweight wall constructions. The DnT,w of a separating wall or floor will typically be of the order 5 to 7 dB lower than the manufacturers specified Rw (single figure quantity of sound insulation) for the single element, due principally to the contribution from flanking sound transmission around the element when it is built on site.

Ctr is the spectrum adaption term. It is a correction attributed to the sound insulation quantity to account for urban traffic noise.

L’nT,w is an in-situ measured performance parameter which demonstrates the level of resistance to impact sound transmission between floors. The impact measurement includes both direct sound transmission and flanking sound transmission.

Further information can be obtained by contacting Soundguard Acoustics or by downloading our FREE developers guide to Approved Doc E sound insulation testing

Thursday, 24 January 2013

What is Sound Insulation Testing?

Sound insulation testing is the assessment of the sound insulation performance of party walls and party floors between different dwellings. Testing is required once the property is nearing final completion and determines if the minimum Building Regulation standard for sound insulation has been met.

Developers are responsible for arranging testing to demonstrate compliance to Building Control that the Approved Doc E sound insulation regulations have been met. The procedure is more commonly referred to as pre-completion testing (PCT) or Approved Document E (ADE) sound testing.

What is Approved Doc E?

Approved Document E – ‘Resistance to the passage of sound’ came into force on July 1st 2003 and provides minimum sound insulation Building Regulation requirement for newly built and converted residential dwellings as well as the Code for Sustainable Homes. Properties include houses, flats, student residences, care homes, hotels and schools.

Approved Document E of the Building Regulations is a government-issued document providing guidance for architects, developers, building control bodies, building services engineers, and others involved in the design and conversion of buildings for residential purpose. The document explains the testing requirement and provides advice and details about building procedures and materials that affect test results


What is the benefit of a Sound Test?

In buildings sound can be defined as 'airborne sound' (i.e. sound generated and transferred directly in the air by talking or home entertainment systems) or 'impact sound' (i.e. sound generated by the impact of an object striking the floor and transmitted through it, such as footfall noise).

The objective of Approved Document E is to raise sound resistance standards for both airborne and impact noise between dwellings to provide reasonable living conditions and improve the standards of acoustic insulation in attached properties

Sound insulation testing may also be required in non-residential buildings such as schools, hospitals and workplaces to ensure that noise sensitive areas such as classrooms, wards and meeting rooms are suitably insulated from noisier areas


Do I need a sound test?

All new and converted dwelling houses and flats for residential purpose require sound testing to Approved Document E standard. This also includes a room or suite of rooms which is not a dwelling house or a flat but which is used by one or more persons to live and sleep. For example, rooms in hostels, hotels, boarding houses, halls of residence, and residential homes.

Detached properties do not require sound testing and new constructions that have been built and appropriately registered with the Robust Details scheme do not need to be sound tested. Historic building conversions may not need to be sound tested but often a ‘test and declare’ certificate for sound insulation performance is requested by the Building Control Officer (BCO).

Friday, 18 January 2013

Soundguards Director gains MSc in Applied Acoustics

Rob Shaddick, Director of Soundguard Acoustics Ltd has gained an MSc in applied acoustics through the University of Derby. The MSc in applied acoustics has proven to be a valuable addition to the company and Robs personal development. Especially in acquisition of expert witness cases and in securing membership and accreditation with the Association of Noise Consultants for Approved Document E pre-completion testing.