A sound insulation test of a separating partition will be considered as a pass if the airborne sound insulation is equal to or greater than the DnT,w + Ctr value required for the appropriate dwelling and if the impact sound insulation is equal to or less than the L’nT,w value for the appropriate dwelling. The performance criteria are different for new builds and conversions and also differences may occur due to the use of the dwelling type.
DnT,w is an in-situ measured performance parameter which demonstrates the level of resistance to sound transmission between two adjacent spaces. The measurement will include both direct sound transmission and flanking sound transmission of the construction. Flanking transmission is the effect of sound travelling through the building and may be particularly evident where beams and joists bridge a common partition or along poorly isolated lightweight wall constructions. The DnT,w of a separating wall or floor will typically be of the order 5 to 7 dB lower than the manufacturers specified Rw (single figure quantity of sound insulation) for the single element, due principally to the contribution from flanking sound transmission around the element when it is built on site.
Ctr is the spectrum adaption term. It is a correction attributed to the sound insulation quantity to account for urban traffic noise.
L’nT,w is an in-situ measured performance parameter which demonstrates the level of resistance to impact sound transmission between floors. The impact measurement includes both direct sound transmission and flanking sound transmission.
Further information can be obtained by contacting Soundguard Acoustics or by downloading our FREE developers guide to Approved Doc E sound insulation testing
Thursday, 28 November 2013
Monday, 18 November 2013
Customer Testimonials for Sound Testing
'Soundguard Acoustics provided a thorough & professional service & achieved a successful outcome for my building refurbishment project. I would definitely recommend them to anyone seeking expertise in this area' D. Widden, Taunton, Somerset
'We found Soundguard Acoustics competent, prompt & professional to work with. We will certainly be working with them again on future projects & would definitely recommend them to fellow professionals' L. Bullivant, BULLCO Ltd, Devon
'Soundguard Acoustics offered clear professional advice on our new product development work with Robust Detail Ltd. They responded quickly and we are very happy with the service received. We would definitely recommend them'M. Panes, Superglass
'Soundguard Acoustics provided a friendly service carried out in a prompt & professional manner' K. Thomas,Weston Super Mare
'We have always had a good service from Soundguard Acoustics. Friendly, reliable & reasonably priced' J. Pearce,DevonBuild.co.uk
'We found Soundguard Acoustics competent, prompt & professional to work with. We will certainly be working with them again on future projects & would definitely recommend them to fellow professionals' L. Bullivant, BULLCO Ltd, Devon
'Soundguard Acoustics offered clear professional advice on our new product development work with Robust Detail Ltd. They responded quickly and we are very happy with the service received. We would definitely recommend them'M. Panes, Superglass
'Soundguard Acoustics provided a friendly service carried out in a prompt & professional manner' K. Thomas,Weston Super Mare
'We have always had a good service from Soundguard Acoustics. Friendly, reliable & reasonably priced' J. Pearce,DevonBuild.co.uk
Friday, 15 November 2013
Approved Doc E Sound Testing - What's involved?
Airborne sound insulation test (walls & floors): A controlled noise is generated by an amplifier and loudspeaker across a broad range of frequencies. The generated noise is very loud and can be in excess of 100dB. Initial measurements are taken using a Sound Level Meter within the ‘source room’ followed by further measurements in the ‘receiver room’ on the other side of the wall or floor under investigation. The source room speaker position is then changed and the measurements repeated either side of the partition under test.
Background noise measurements are made using a sound level meter in the receiving room and are used to apply appropriate corrections for external sound such as traffic noise. Similarly the reverberation time (the time taken for sound to decay by 60dB) is measured within the receiving room using the sound source and a sound level meter to determine the corrections that must be applied to account for the characteristics and absorptiveness of the room.
The difference in the two airborne noise levels (for walls and floors), corrected for background and reverberation characteristics determines the airborne sound insulation performance of the wall, or floor. A greater airborne noise difference between the source room and the receiver room determines a higher airborne sound insulation performance.
Impact sound transmission test (floors only): This test is different, a calibrated ‘tapping machine’ which comprises of five 'hammers' driven up and down by a cam and electric motor is used to "tap" the floor surface by applying a known force on the floor structure. The machine is placed in several pre-determined positions. The resulting noise is measured in the dwelling below, using a sound level meter.
Background noise measurements are made using a sound level meter in the receiving room and are used to apply appropriate corrections for external sound such as traffic noise. Similarly the reverberation time (the time taken for sound to decay by 60dB) is measured within the receiving room using the sound source and a sound level meter to determine the corrections that must be applied to account for the characteristics and absorptiveness of the room.
The measured noise levels in the receiving room (for impact floors tests), corrected for background and reverberation characteristics determines the impact sound insulation performance of the floor. For the impact noise the lower the measured level, the better the performance as less sound is being transmitted into the dwelling below.
Find out more about Sound Testing or contact Soundguard Acoustics
Sound Test DEVON | Sound Test CORNWALL | Sound Test SOMERSET | Sound Test DORSET | Sound Test SOUTH WEST | Sound Test UK
Background noise measurements are made using a sound level meter in the receiving room and are used to apply appropriate corrections for external sound such as traffic noise. Similarly the reverberation time (the time taken for sound to decay by 60dB) is measured within the receiving room using the sound source and a sound level meter to determine the corrections that must be applied to account for the characteristics and absorptiveness of the room.
The difference in the two airborne noise levels (for walls and floors), corrected for background and reverberation characteristics determines the airborne sound insulation performance of the wall, or floor. A greater airborne noise difference between the source room and the receiver room determines a higher airborne sound insulation performance.
Impact sound transmission test (floors only): This test is different, a calibrated ‘tapping machine’ which comprises of five 'hammers' driven up and down by a cam and electric motor is used to "tap" the floor surface by applying a known force on the floor structure. The machine is placed in several pre-determined positions. The resulting noise is measured in the dwelling below, using a sound level meter.
Background noise measurements are made using a sound level meter in the receiving room and are used to apply appropriate corrections for external sound such as traffic noise. Similarly the reverberation time (the time taken for sound to decay by 60dB) is measured within the receiving room using the sound source and a sound level meter to determine the corrections that must be applied to account for the characteristics and absorptiveness of the room.
The measured noise levels in the receiving room (for impact floors tests), corrected for background and reverberation characteristics determines the impact sound insulation performance of the floor. For the impact noise the lower the measured level, the better the performance as less sound is being transmitted into the dwelling below.
Find out more about Sound Testing or contact Soundguard Acoustics
Sound Test DEVON | Sound Test CORNWALL | Sound Test SOMERSET | Sound Test DORSET | Sound Test SOUTH WEST | Sound Test UK
Thursday, 14 November 2013
Where do I find an Approved Doc E Sound Testing company?
Approved Document E states that the sound insulation testing body should be either a member of the Association of Noise Consultants (ANC) and have joined their PCT registration scheme or be registered testers with the United Kingdom Accreditation Service (UKAS).
Choosing an accredited company under these schemes gives you the peace of mind that your reports will be accepted by all local authorities, building control and national guarantee companies.
By using an ANC member registered under the PCT registration scheme, such as Soundguard Acoustics Ltd, then you will receive a full report including instruction for your Building Control Officer for accessing the secure online testing certificates for your build. Our company, Soundguard Acoustics, will also liaise with and release the report directly to your BCO if required to ensure that they are satisfied with the test selection.
What if I use an unregistered company?
Don’t! The quality and validity of the testing and results may be questionable and may not be accepted by the necessary approval bodies. It is likely that your BCO will ask for further or repeated testing by an accredited test company to validate the results. This will result in delay for your project and further payment to the accredited test company.
Choosing an accredited company under these schemes gives you the peace of mind that your reports will be accepted by all local authorities, building control and national guarantee companies.
By using an ANC member registered under the PCT registration scheme, such as Soundguard Acoustics Ltd, then you will receive a full report including instruction for your Building Control Officer for accessing the secure online testing certificates for your build. Our company, Soundguard Acoustics, will also liaise with and release the report directly to your BCO if required to ensure that they are satisfied with the test selection.
What if I use an unregistered company?
Don’t! The quality and validity of the testing and results may be questionable and may not be accepted by the necessary approval bodies. It is likely that your BCO will ask for further or repeated testing by an accredited test company to validate the results. This will result in delay for your project and further payment to the accredited test company.
Wednesday, 13 November 2013
How many Approved Doc E sound tests do I need within my development?
One set of tests needs to be undertaken for every ten flats or houses, provided the construction system is the same. A set means that the test should include two locations where the party element (wall or floor) is tested.
This is equivalent to two individual tests when assessing the performance of a wall (airborne performance only) and four individual tests when assessing a floor (two airborne and two impact tests). All tests must be undertaken between habitable spaces (e.g. bedrooms, living rooms) and not to or from common spaces such as stairwells and corridors.
Approved Document E 2003 states that a minimum of 10% of all party walls and floors is sound tested for every construction group or sub-group. This means that where variations in the construction may occur then further testing may be required.
Houses: a set of tests would usually comprise of two airborne sound insulation tests of a pair of separating walls
Flats: a set of tests would usually comprise of two airborne sound insulation tests on separating walls; two airborne sound insulation tests of separating floors and two impact sound transmission tests of separating floors
Rooms for Residential Purposes: (student residences, hotel rooms & care homes) a set of tests would usually comprise of one airborne sound insulation test of a separating wall; one airborne sound insulation test of a separating floor and one impact sound transmission test of a separating floor
Contact Soundguard Acoustics today for your advice or quotation for your testing requirements EMAIL
Wednesday, 23 October 2013
Acoustics & floor insulation design
Sound insulation of floors between flats are a common concern for
developers. With a multitude of products on offer within the market
place understanding the effects of each material upon the impact
insulation and airborne insulation can catch out the unwary developer.
This can lead to expensive retro-fit products following a set of sound
testing failures or simply the purchase of materials that may absolutely
no difference! The concept of floor design
does need to include the effects of other flanking pathways, especially
where light-weight walls, service penetrations, downlighters, surface
finishes and reduced ceiling heights has to be considered. Soundguard
Acoustics can work with developers from preliminary ideas to final
finish ensuring that your property will achieve the sound insulation
requirements of Approved Document E whilst not making any expensive mistakes.
Approved Doc E Sound Testing
Approved Document E – ‘Resistance to the passage of sound’ came into force on July 1st 2003 and provides minimum sound insulation Building Regulation requirement for newly built and converted residential dwellings as well as the Code for Sustainable Homes. Properties include houses, flats, student residences, care homes, hotels and schools.
Approved Document E of the Building Regulations is a government-issued document providing guidance for architects, developers, building control bodies, building services engineers, and others involved in the design and conversion of buildings for residential purpose. The document explains the sound testing requirement and provides advice and details about building procedures and materials that affect test results.
Devon based, Soundguard Acoustics Ltd is approved under the Association of Noise Consultants (ANC) registration scheme for carrying out sound insulation testing (Registration number: 194-01) and will carry out sound tests across the South West and the UK.
The ANC scheme is supported by Approved Document E and ensures that sound insulation tests are carried out by suitably qualified and experienced staff, in accordance with the appropriate standards.
The scheme ensures that sound tests are properly traceable, audited and that you receive a fully documented report and certificate which will be easily recognised for approval by your local Building Control department.
If you require further advice with your project or end of build sound testing then please contact us.
Ssshhh – Soundguard New Website Launch
Soundguard Acoustics Ltd was launched in 2008. Since this time our range of services has increased and our new website, launched in October 2013, reflects these changes. Our experience within new areas such as wind turbine assessment and festival management now deserve their own pages and the useful addition of free downloads and a wide portfolio provides you with a greater insight into our acoustic services. Like many modern and forward thinking businesses, Soundguard Acoustics Ltd has embraced the social media generation, and you can now keep up to date with us on Twitter, Google+, Facebook and LinkedIn. www.soundguard.co.uk
Monday, 22 July 2013
Agents Required - For your 'ears' only
Become an Insta-Mold Secret Agent: For your 'ears' only
It has long been considered that Custom Hearing Protection attracts a customised price tag! Insta-Mold is changing this
fact and for the first time in the UK and Ireland direct moulded custom hearing
protection that meet CE can be supplied within hours and at a fraction of the
cost of lab-moulded products.
The versatility of Insta-Mold
determines that the NHS can supply ‘swim-plugs’ or custom hearing protection in
as little as 2 hours. The industrial sector can manage their own in-house
custom hearing protection programmes and fit all their employees at a fraction
of the price and custom hearing protection can be made on site at private weekend
shooting events, festivals or motorcycle meetings.
Insta-Mold products can be manufactured
and supplied by anyone who has appropriate ear impression experience or qualification.
The medical grade, two-part, hypo-allergenic, ‘Insta-Mold’ silicone is direct
moulded into the ear to form a CE certified custom hearing protection product
that is lacquer coated and fitted with optional acoustic filters. With a Single
Number Rating (SNR) of between 20dB and 29dB and with a life expectancy of up
to four years then they are well suited for most applications. Insta-Mold products include ‘snag-free’ safety
leashes and fully traceable options for the food and drinks industry, and if
you are supplying to the water-sport market then they float too! The wide colour
range and swirl effects finally provide a product that not only meets the comfort
needs of the wearer but makes a real statement too.
Audiologists, Hearing Aid Dispensers,
Occupational Nurses, Hearing Therapists and any individual that has appropriate
ear-impression training can become an Insta-Mold Agent and manufacture direct
moulded hearing protection devices within hours and without the significant set
up facilities of an ear-mould lab. This is of particular benefit to the NHS in
the application of swimmers earplugs or industrial contracts which can be
managed in-house and at a fraction of the cost of lab-moulded products. The
product also provides a custom moulded option with excellent profit margins for
the private hearing sector markets.
For more details, pricing and how to
become an Insta-Mold agent then please contact 0845 653 0233 or visit the
website at www.InstaMold.co.uk or www.soundguard.co.uk
Thursday, 24 January 2013
What is Sound Insulation Testing?
Developers are responsible for arranging testing to demonstrate compliance to Building Control that the Approved Doc E sound insulation regulations have been met. The procedure is more commonly referred to as pre-completion testing (PCT) or Approved Document E (ADE) sound testing.
What is Approved Doc E?
Approved Document E – ‘Resistance to the passage of sound’ came into force on July 1st 2003 and provides minimum sound insulation Building Regulation requirement for newly built and converted residential dwellings as well as the Code for Sustainable Homes. Properties include houses, flats, student residences, care homes, hotels and schools.
Approved Document E of the Building Regulations is a government-issued document providing guidance for architects, developers, building control bodies, building services engineers, and others involved in the design and conversion of buildings for residential purpose. The document explains the testing requirement and provides advice and details about building procedures and materials that affect test results
What is the benefit of a Sound Test?
In buildings sound can be defined as 'airborne sound' (i.e. sound generated and transferred directly in the air by talking or home entertainment systems) or 'impact sound' (i.e. sound generated by the impact of an object striking the floor and transmitted through it, such as footfall noise).
The objective of Approved Document E is to raise sound resistance standards for both airborne and impact noise between dwellings to provide reasonable living conditions and improve the standards of acoustic insulation in attached properties
Sound insulation testing may also be required in non-residential buildings such as schools, hospitals and workplaces to ensure that noise sensitive areas such as classrooms, wards and meeting rooms are suitably insulated from noisier areas
Do I need a sound test?
All new and converted dwelling houses and flats for residential purpose require sound testing to Approved Document E standard. This also includes a room or suite of rooms which is not a dwelling house or a flat but which is used by one or more persons to live and sleep. For example, rooms in hostels, hotels, boarding houses, halls of residence, and residential homes.
Detached properties do not require sound testing and new constructions that have been built and appropriately registered with the Robust Details scheme do not need to be sound tested. Historic building conversions may not need to be sound tested but often a ‘test and declare’ certificate for sound insulation performance is requested by the Building Control Officer (BCO).
Is my build ready for a Sound Test?
Sound insulation tests are undertaken when the development is “pre-completed”. This
means that the test
rooms should
be at a stage where just final finishing, such as painting and carpets are
required.
Soundguard Acoustics has provided a site checklist below
to assist you with this. By ensuring that you meet the requirements of the
checklist then the build can be deemed to be at a stage ready for soundinsulation testing. Where items are not in place this will negatively affect
the sound insulation performance of the build.
- Windows should be fully installed, glazed & closable
- Trickle vents and other ventilation systems should be fitted
- Internal & external doors must be hung, glazed & closable
- All wall, floors & ceiling constructions must be completed
- Skirting boards should all be fitted & cornice where fitted
- Electrical sockets, TV Aerial sockets & light switches should be fitted
- Rooms must be clear of building materials, tools & unfurnished
- No cosmetic floor coverings should be fitted (i.e. laminate, carpet, vinyl, ceramics)
- No trades should be working in the dwellings during the tests
- Access to rooms either side of the separating structure is essential
- Non-tester access to the rooms is prohibited during testing
- No noisy operations (drilling, cutting or groundwork) to occur nearby during testing
- Provision of 240v 50Hz mains power is required within the dwellings
How many sound tests do I need?
One set of sound tests needs to
be undertaken for every ten flats or houses, provided the construction system
is the same. A set means that the test should
include two locations where the party element (wall or floor) is tested.
This is equivalent to two
individual sound tests when assessing the performance of a wall (airborne performance
only) and four individual tests when assessing a floor (two airborne and two
impact tests). All tests must be
undertaken between habitable spaces (e.g. bedrooms, living rooms) and not to or
from common spaces such as stairwells and corridors.
Approved Document E 2003 states that a
minimum of 10% of all party walls and floors is sound tested for every
construction group or sub-group. This means that where variations in the
construction may occur then further testing may be required.
- Houses: a set of tests would usually comprise of two airborne sound insulation tests of a pair of separating walls
- Flats:a set of tests would usually comprise of two airborne sound insulation tests on separating walls; two airborne sound insulation tests of separating floors and two impact sound transmission tests of separating floors
- Rooms for Residential Purposes: (student residences, hotel rooms & care homes) a set of tests would usually comprise of one airborne sound insulation test of a separating wall; one airborne sound insulation test of a separating floor and one impact sound transmission test of a separating floor